Airsoft Canada
https://blackblitzairsoft.myshopify.com/

Go Back   Airsoft Canada > Discussion > Doctor's Corner
Home Forums Register Gallery FAQ Calendar
Retailers Community News/Info International Retailers IRC Today's Posts

ICS M4 firing issues

:

Doctor's Corner

Reply
 
Thread Tools
Old September 28th, 2009, 22:32   #1
delta76
 
delta76's Avatar
 
Join Date: Dec 2008
Location: Toronto
ICS M4 firing issues

I'm experiencing issues with misfiring in an ICS M4. The gun was functioning perfectly until I recently installed a metal body.

This issue is confusing because most of the usual variables don't seem to apply. The first shot jams (I'm assuming in the hop-unit and the next shot bumps it out and it falls out of the barrel and subsequent shots do the same until the mag is removed and the final chambered round is shot out with normal fps. The mag is obviously feeding and there are no issues with air seal as the final shot consistently fires at normal fps. The tappet plate is fine, the hop-up rubber is in great shape and properly installed, I installed a modify nozzle and replaced it with the original ICS nozzle to make sure any compatibility issues weren't to blame (same issues with the stock nozzle). I'm wondering if ICS require propriatary sleeves? I've got a guarder clear installed, could that be causing the jamming? Has anyone experienced similar issues when installing a metal body or misfiring with ICS propriatary hop-ups?
delta76 is offline   Reply With Quote
Old September 29th, 2009, 13:43   #2
Skladfin
 
Skladfin's Avatar
 
Join Date: Dec 2006
Location: Glace Bay, Nova Scotia
which metal body did install(question mark dont work lol)
Skladfin is offline   Reply With Quote
Old September 29th, 2009, 13:55   #3
delta76
 
delta76's Avatar
 
Join Date: Dec 2008
Location: Toronto
It's an older generation Olympic Arms body.
delta76 is offline   Reply With Quote
Old September 29th, 2009, 16:40   #4
Kos-Mos
 
Kos-Mos's Avatar
 
Join Date: Nov 2005
Location: LĂ©vis (QC)
Double check for a crack in the hop-up body.

also, if your mechbox do not have a hole to install the cross-pin (if you have the black lower mechbox) it is needed when using the older metal bodies.

You can simply make the hole, but make sure you are certain where to make it.
__________________
Quote:
Originally Posted by Drake View Post
Damnit, don't make me add "no discussing temporal paradoxes" to the rules or I'll go back in time and ban you last week.
Kos-Mos is offline   Reply With Quote
Old September 29th, 2009, 17:34   #5
delta76
 
delta76's Avatar
 
Join Date: Dec 2008
Location: Toronto
Quote:
Originally Posted by Kos-Mos View Post
Double check for a crack in the hop-up body.

also, if your mechbox do not have a hole to install the cross-pin (if you have the black lower mechbox) it is needed when using the older metal bodies.

You can simply make the hole, but make sure you are certain where to make it.

Well that is news to me. I got the mechbox pin with the body and realized I couldn't make use of it (I do have the black lower mechbox). Thanks for the info, I'm guessing the issue is the mechbox is sitting too loosely in the body? Although the upper mechbox is extremely firm in the body and serves to hold the lower in place.
delta76 is offline   Reply With Quote
Old September 30th, 2009, 07:25   #6
testtube
A Total Bastard
 
testtube's Avatar
 
Join Date: Apr 2003
Location: Ottawa,Ont
Send a message via MSN to testtube
it's either a barel alignment problem or as stated the mechbox is floating.
testtube is offline   Reply With Quote
ReplyTop


Go Back   Airsoft Canada > Discussion > Doctor's Corner

Bookmarks


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off


Airsoft Canada
https://blackblitzairsoft.myshopify.com/

All times are GMT -4. The time now is 00:52.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.